Advanced Thermal Profiler 80000 Data Point/Channel 0.1C Resolution RF Transceiver Hi-Temp Adhesive Tape
Intorduction
1. Thermal profiler 2. Insulation box
3. Temperature test line 4. Data download line
5. Charger 6. Hi-temp adhesive tape
7. Software CD 8. “+” screwdriver 9. Tweezers
10. Insulated gloves 11. Solder wire
12. Scissors 13. Instrument box
14. User Manual 15. Acceptance Certificate
16. RF Transceiver (Choose Composition)
17. Wave Test System (Choose Composition)
Main Technical Specifications
1,Thermocouple: K-type thermocouple
2,Sampling interval:0.05sec---600sec Set with software
3,Record data:80000 point/channel, Can record 20 sets profile
4,Resolution: 0.1℃
5,Temperature measuring range: 0—1000℃
6,Temperature measuring accuracy: ±1.0℃
7,Total power: ≤120mW
8,Operating voltage:3.6VDC, rechargeable battery
9,Dimensions: 195(L)×82(W)×21(H)mm 195(L)×103(W)×21(H)mm
10, Insulation box:245(L)×100(W)×30(H)mm
10,Start Mode : Manual, specified time or specified temperature
11,Record mode: Monitor/Record
12,Connection mode:USB/RF
13,Software version:Profilermanager 2.0
Product Library Manager
Machine Library Manager
Solder Library Manager
Recipe Library Manager
Data analysis
PWI
Peak Temp,Times of overtop the Temp
Times of between Temp(Reflow)
Slope of between Temp(Reflow)
Slope of between Times(Wave)
Operating Methods
1.Firstly, check whether the battery power is sufficient, if it is
lower than 20% you have to charge it first, secondly, if the
surface temperature of the instrument is higher than 45℃C please
don't charge it, try to charge it at room temperature.
2. Typical causes of problems when establishing communication
links:Communication cable not fully inserted - make sure the
correct jack is used. Communication cable or connector is damaged -
check for breaks or other damage. Battery is not charging I Charge.
and make sure the charging LED is on.
3. The thermal barrier can withstand a maximum of 9 minutes at 280°
C. Be sure to exceed this range and ensure that the internal
temperature of the instrument does not exceed 85° C.
4. When not in use for a long time, please observe whether the data
indicator light flashes every 5 seconds or so, if it does, please
press and hold down the "start" end key for about 5 seconds until
the indicator light suddenly flashes, and then observe it until
there is no light flashing.
5. Please make sure to cover the heat insulation box when crossing
the furnace, and wait for the time to arrive.
6. You can only connect one Oven Tester logger to the computer at a
time. Can not be connected to the computer at the same time more
than one recorder to the same USB port and then choose one of them.
7. After a furnace again over the furnace, and so on the thermal
barrier box cooled down before use.